APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet — APC
APC

APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet

Part number UPA-APDU11350ME

$3,331.95 RRP $3,987.50 Save $655.55

Includes GST · $302.90 GST

Low stock (5)

Ships from an interstate branch — $35, 1–3 business days. Express is not available on this item right now because the stock is not in a local warehouse.

Need it installed? Ask for a supply-and-install quote — usually cheaper than sourcing an installer separately.

Description

APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet


APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. PDU level power metering provides power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2 in. (5.6 cm) wide form factor allows for more equipment in the rack. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). A 10-foot (3-meter) input cord makes it easier for the PDU to reach the power supply. Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today's high-density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model’s input power cord is IEC-309 32 A 3P+N+PE and features 24 count C13/C15/C19/C21 combo outlets and 24 count C13/C15 outlets.

Colour
Black
Product or component type
PDU
PDU type
Metered
Cord length
3 m
Complementary
Input Voltage
415 V 3 phases
400 V 3 phases
Height
1780 mm
Width
56 mm
Output Voltage
240 V
Depth
75 mm
Net weight
8.4 kg
Mounting location
Side
Mounting preference
No preference
Input Plug Type
IEC 60309 30 A 3P + N + PE
Mounting mode
Rack-mounted
Rack units
0U
Mounting position
Vertical
Communication port protocol
1000BASE-T
10/100BASE-T
[In] rated current
24 A
permissible voltage
200…240 V
346…415 V
Input current limits
30 A
Load capacity
17300 VA
Network frequency
50/60 Hz
Outlet type and quantity
24 C13/C15/C19/C21
24C13/C15
Environment
Standards
UL 62368-1
CSA C22.2 No 62368-1
FCC part 15 Subpart B
CE
EN 62368-1
IP degree of protection
IP44
Ambient air temperature for operation
-5…60 °C
Relative humidity
5…95 %
Operating altitude
0...10000 ft
Ambient air temperature for storage
-25…65 °C
Storage Relative Humidity
5…95 %
Storage altitude
0…15240 m
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
198 cm
Package 1 Width
13.2 cm
Package 1 Length
26.2 cm
Package 1 Weight
11.4 kg
Contractual warranty
Warranty (in months)
36
  • Australia-wide deliveryMelbourne metro typically 1–3 business days.
  • Full manufacturer warrantyWe administer claims for you.
  • Installed by the people who sell itAsk for a combined supply-and-install price.

More like this

Others in Data Racks & Accessories

Want this installed properly?

We install this equipment on Melbourne sites every week. Ask for a supply-and-install quote and you get one supplier, one warranty conversation and a system commissioned by the people who sold it to you.

Get in touch

Ask about APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet

Quantities, lead time, compatibility or a supply-and-install price on the UPA-APDU11350ME — send it through and we will come back the same business day.

  • Trade-informed pricingDistributor cost plus a transparent margin, not a retail markup.
  • Anything in the rangeThe catalogue online is a fraction of what we can order — ask for a part number.
  • Supply and installWant it fitted? Ask for a combined quote; the labour is usually where the saving is.
  • Australia-wide deliveryMelbourne metro 1–3 business days, with express where the stock is local.

We reply within one business day. Your details are used only to answer this enquiry — see our privacy policy. Protected by reCAPTCHA.

Reviews

Rated by Melbourne businesses

Shop now Service call Call